Pneumonia Detection Using Chest Radiographs With Novel EfficientNetV2L Model
Artículo
Materias > Ingeniería
Universidad Europea del Atlántico > Investigación > Producción Científica
Fundación Universitaria Internacional de Colombia > Investigación > Artículos y libros
Universidad Internacional Iberoamericana México > Investigación > Producción Científica
Universidad Internacional Iberoamericana Puerto Rico > Investigación > Producción Científica
Universidad Internacional do Cuanza > Investigación > Producción Científica
Abierto
Inglés
Pneumonia is a potentially life-threatening infectious disease that is typically diagnosed through physical examinations and diagnostic imaging techniques such as chest X-rays, ultrasounds or lung biopsies. Accurate diagnosis is crucial as wrong diagnosis, inadequate treatment or lack of treatment can cause serious consequences for patients and may become fatal. The advancements in deep learning have significantly contributed to aiding medical experts in diagnosing pneumonia by assisting in their decision-making process. By leveraging deep learning models, healthcare professionals can enhance diagnostic accuracy and make informed treatment decisions for patients suspected of having pneumonia. In this study, six deep learning models including CNN, InceptionResNetV2, Xception, VGG16, ResNet50 and EfficientNetV2L are implemented and evaluated. The study also incorporates the Adam optimizer, which effectively adjusts the epoch for all the models. The models are trained on a dataset of 5856 chest X-ray images and show 87.78%, 88.94%, 90.7%, 91.66%, 87.98% and 94.02% accuracy for CNN, InceptionResNetV2, Xception, VGG16, ResNet50 and EfficientNetV2L, respectively. Notably, EfficientNetV2L demonstrates the highest accuracy and proves its robustness for pneumonia detection. These findings highlight the potential of deep learning models in accurately detecting and predicting pneumonia based on chest X-ray images, providing valuable support in clinical decision-making and improving patient treatment.
metadata
Ali, Mudasir; Shahroz, Mobeen; Akram, Urooj; Mushtaq, Muhammad Faheem; Carvajal-Altamiranda, Stefanía; Aparicio Obregón, Silvia; Díez, Isabel De La Torre y Ashraf, Imran
mail
SIN ESPECIFICAR, SIN ESPECIFICAR, SIN ESPECIFICAR, SIN ESPECIFICAR, stefania.carvajal@uneatlantico.es, silvia.aparicio@uneatlantico.es, SIN ESPECIFICAR, SIN ESPECIFICAR
(2024)
Pneumonia Detection Using Chest Radiographs With Novel EfficientNetV2L Model.
IEEE Access, 12.
pp. 34691-34707.
ISSN 2169-3536
|
Texto
Pneumonia_Detection_Using_Chest_Radiographs_With_Novel_EfficientNetV2L_Model.pdf Available under License Creative Commons Attribution Non-commercial No Derivatives. Descargar (2MB) |
Resumen
Pneumonia is a potentially life-threatening infectious disease that is typically diagnosed through physical examinations and diagnostic imaging techniques such as chest X-rays, ultrasounds or lung biopsies. Accurate diagnosis is crucial as wrong diagnosis, inadequate treatment or lack of treatment can cause serious consequences for patients and may become fatal. The advancements in deep learning have significantly contributed to aiding medical experts in diagnosing pneumonia by assisting in their decision-making process. By leveraging deep learning models, healthcare professionals can enhance diagnostic accuracy and make informed treatment decisions for patients suspected of having pneumonia. In this study, six deep learning models including CNN, InceptionResNetV2, Xception, VGG16, ResNet50 and EfficientNetV2L are implemented and evaluated. The study also incorporates the Adam optimizer, which effectively adjusts the epoch for all the models. The models are trained on a dataset of 5856 chest X-ray images and show 87.78%, 88.94%, 90.7%, 91.66%, 87.98% and 94.02% accuracy for CNN, InceptionResNetV2, Xception, VGG16, ResNet50 and EfficientNetV2L, respectively. Notably, EfficientNetV2L demonstrates the highest accuracy and proves its robustness for pneumonia detection. These findings highlight the potential of deep learning models in accurately detecting and predicting pneumonia based on chest X-ray images, providing valuable support in clinical decision-making and improving patient treatment.
| Tipo de Documento: | Artículo |
|---|---|
| Palabras Clave: | Pneumonia detection, transfer learning, efficientnetv2l, data augmentation, chest X-rays |
| Clasificación temática: | Materias > Ingeniería |
| Divisiones: | Universidad Europea del Atlántico > Investigación > Producción Científica Fundación Universitaria Internacional de Colombia > Investigación > Artículos y libros Universidad Internacional Iberoamericana México > Investigación > Producción Científica Universidad Internacional Iberoamericana Puerto Rico > Investigación > Producción Científica Universidad Internacional do Cuanza > Investigación > Producción Científica |
| Depositado: | 12 Abr 2024 23:30 |
| Ultima Modificación: | 12 Abr 2024 23:30 |
| URI: | https://repositorio.unincol.edu.co/id/eprint/11666 |
Acciones (logins necesarios)
![]() |
Ver Objeto |
<a href="/17862/1/sensors-25-06419.pdf" class="ep_document_link"><img class="ep_doc_icon" alt="[img]" src="/style/images/fileicons/text.png" border="0"/></a>
en
open
Edge-Based Autonomous Fire and Smoke Detection Using MobileNetV2
Forest fires pose significant threats to ecosystems, human life, and the global climate, necessitating rapid and reliable detection systems. Traditional fire detection approaches, including sensor networks, satellite monitoring, and centralized image analysis, often suffer from delayed response, high false positives, and limited deployment in remote areas. Recent deep learning-based methods offer high classification accuracy but are typically computationally intensive and unsuitable for low-power, real-time edge devices. This study presents an autonomous, edge-based forest fire and smoke detection system using a lightweight MobileNetV2 convolutional neural network. The model is trained on a balanced dataset of fire, smoke, and non-fire images and optimized for deployment on resource-constrained edge devices. The system performs near real-time inference, achieving a test accuracy of 97.98% with an average end-to-end prediction latency of 0.77 s per frame (approximately 1.3 FPS) on the Raspberry Pi 5 edge device. Predictions include the class label, confidence score, and timestamp, all generated locally without reliance on cloud connectivity, thereby enhancing security and robustness against potential cyber threats. Experimental results demonstrate that the proposed solution maintains high predictive performance comparable to state-of-the-art methods while providing efficient, offline operation suitable for real-world environmental monitoring and early wildfire mitigation. This approach enables cost-effective, scalable deployment in remote forest regions, combining accuracy, speed, and autonomous edge processing for timely fire and smoke detection.
Dilshod Sharobiddinov mail , Hafeez Ur Rehman Siddiqui mail , Adil Ali Saleem mail , Gerardo Méndez Mezquita mail , Debora L. Ramírez-Vargas mail debora.ramirez@unini.edu.mx, Isabel de la Torre Díez mail ,
Sharobiddinov
<a href="/17849/1/1-s2.0-S2590005625001043-main.pdf" class="ep_document_link"><img class="ep_doc_icon" alt="[img]" src="/style/images/fileicons/text.png" border="0"/></a>
en
open
Ultra Wideband radar-based gait analysis for gender classification using artificial intelligence
Gender classification plays a vital role in various applications, particularly in security and healthcare. While several biometric methods such as facial recognition, voice analysis, activity monitoring, and gait recognition are commonly used, their accuracy and reliability often suffer due to challenges like body part occlusion, high computational costs, and recognition errors. This study investigates gender classification using gait data captured by Ultra-Wideband radar, offering a non-intrusive and occlusion-resilient alternative to traditional biometric methods. A dataset comprising 163 participants was collected, and the radar signals underwent preprocessing, including clutter suppression and peak detection, to isolate meaningful gait cycles. Spectral features extracted from these cycles were transformed using a novel integration of Feedforward Artificial Neural Networks and Random Forests , enhancing discriminative power. Among the models evaluated, the Random Forest classifier demonstrated superior performance, achieving 94.68% accuracy and a cross-validation score of 0.93. The study highlights the effectiveness of Ultra-wideband radar and the proposed transformation framework in advancing robust gender classification.
Adil Ali Saleem mail , Hafeez Ur Rehman Siddiqui mail , Muhammad Amjad Raza mail , Sandra Dudley mail , Julio César Martínez Espinosa mail ulio.martinez@unini.edu.mx, Luis Alonso Dzul López mail luis.dzul@uneatlantico.es, Isabel de la Torre Díez mail ,
Saleem
<a class="ep_document_link" href="/17864/1/s10115-025-02588-y.pdf"><img class="ep_doc_icon" alt="[img]" src="/style/images/fileicons/text.png" border="0"/></a>
en
open
Advancing fake news combating using machine learning: a hybrid model approach
The digital era, while offering unparalleled access to information, has also seen the rapid proliferation of fake news, a phenomenon with the potential to distort public perception and influence sociopolitical events. The need to identify and mitigate the spread of such disinformation is crucial for maintaining the integrity of public discourse. This research introduces a multi-view learning framework that achieves high precision by systematically integrating diverse feature perspectives. Using a diverse dataset of news articles, the approach combines several feature extraction methods, including TF-IDF for individual words (unigrams) and word pairs (bigrams), and counts vectorization to represent text in multiple ways. To capture additional linguistic and semantic information, advanced features, such as readability scores, sentiment scores, and topic distributions generated by latent Dirichlet allocation (LDA), are also extracted. The framework implements a multi-view learning strategy, where separate views focus on basic text, linguistic, and semantic features, feeding into a final ensemble model. Models like logistic regression, random forest, and LightGBM are employed to analyze each view, and a stacked ensemble integrates their outputs. Through rigorous tenfold cross-validation, our proposed multi-view ensemble achieves a state-of-the-art accuracy of 0.9994, outperforming strong baselines, including single-view models and a BERT-based classifier. Robustness testing confirms the model maintains high accuracy even under data perturbations, establishing the value of structured feature separation and intelligent ensemble techniques.
Zahid Aslam mail , Malik Muhammad Saad Missen mail , Arslan Abdul Ghaffar mail , Arif Mehmood mail , Mónica Gracia Villar mail monica.gracia@uneatlantico.es, Eduardo René Silva Alvarado mail eduardo.silva@funiber.org, Imran Ashraf mail ,
Aslam
<a class="ep_document_link" href="/17865/1/International%20Journal%20of%20Intelligent%20Systems%20-%202025%20-%20Shafi%20-%20Scalable%20Comprehensive%20Automatic%20Inspection%20%20Cleaning%20%20and.pdf"><img class="ep_doc_icon" alt="[img]" src="/style/images/fileicons/text.png" border="0"/></a>
en
open
Cleaning and inspection of pipelines and gun barrels are crucial for ensuring safety and integrity to extend their lifespan. Existing automatic inspection approaches lack high robustness, as well as portability, and have movement restrictions and complexity. This study presents the design and development of a scalable, comprehensive automated inspection, cleaning, and evaluation mechanism (CAICEM) for large-sized pipelines and barrels with diameters in the range of 105 mm–210 mm. The proposed system is divided into electrical and mechanical assemblies that are independently designed, tested, fabricated, integrated, and controlled with industrial grid controllers and processors. These actuators are suitably programmed to provide the desired actions through toggle switches on a simple housing subassembly. The stress analysis and material specifications are obtained using ANSYS to ensure robustness and practicability. Later, on-ground testing and optimization are performed before industrial prototyping. The inspection system of the proposed mechanism includes barrel-mounted and brush-mounted cameras with sensors utilized to keep track of the pipeline deposits and monitor user activity. The experimental results demonstrate that the proposed mechanism is cost-effective and achieves the desired objectives with minimum human efforts in the least possible time for both smooth and rifled large-diameter pipes and barrels.
Imran Shafi mail , Imad Khan mail , Jose Breñosa mail josemanuel.brenosa@uneatlantico.es, Miguel Ángel López Flores mail , Julio César Martínez Espinosa mail ulio.martinez@unini.edu.mx, Jin-Ghoo Choi mail , Imran Ashraf mail , Richard Murray mail ,
Shafi
<a href="/17831/1/s43856-025-01020-4.pdf" class="ep_document_link"><img class="ep_doc_icon" alt="[img]" src="/style/images/fileicons/text.png" border="0"/></a>
en
open
Association between blood cortisol levels and numerical rating scale in prehospital pain assessment
Background Nowadays, there is no correlation between levels of cortisol and pain in the prehospital setting. The aim of this work was to determine the ability of prehospital cortisol levels to correlate to pain. Cortisol levels were compared with those of the numerical rating scale (NRS). Methods This is a prospective observational study looking at adult patients with acute disease managed by Emergency Medical Services (EMS) and transferred to the emergency department of two tertiary care hospitals. Epidemiological variables, vital signs, and prehospital blood analysis data were collected. A total of 1516 patients were included, the median age was 67 years (IQR: 51–79; range: 18–103) with 42.7% of females. The primary outcome was pain evaluation by NRS, which was categorized as pain-free (0 points), mild (1–3), moderate (4–6), or severe (≥7). Analysis of variance, correlation, and classification capacity in the form area under the curve of the receiver operating characteristic (AUC) curve were used to prospectively evaluate the association of cortisol with NRS. Results The median NRS and cortisol level are 1 point (IQR: 0–4) and 282 nmol/L (IQR: 143–433). There are 584 pain-free patients (38.5%), 525 mild (34.6%), 244 moderate (16.1%), and 163 severe pain (10.8%). Cortisol levels in each NRS category result in p < 0.001. The correlation coefficient between the cortisol level and NRS is 0.87 (p < 0.001). The AUC of cortisol to classify patients into each NRS category is 0.882 (95% CI: 0.853–0.910), 0.496 (95% CI: 0.446–0.545), 0.837 (95% CI: 0.803–0.872), and 0.981 (95% CI: 0.970–0.991) for the pain-free, mild, moderate, and severe categories, respectively. Conclusions Cortisol levels show similar pain evaluation as NRS, with high-correlation for NRS pain categories, except for mild-pain. Therefore, cortisol evaluation via the EMS could provide information regarding pain status.
Raúl López-Izquierdo mail , Elisa A. Ingelmo-Astorga mail , Carlos del Pozo Vegas mail , Santos Gracia Villar mail santos.gracia@uneatlantico.es, Luis Alonso Dzul López mail luis.dzul@uneatlantico.es, Silvia Aparicio Obregón mail silvia.aparicio@uneatlantico.es, Rubén Calderón Iglesias mail ruben.calderon@uneatlantico.es, Ancor Sanz-García mail , Francisco Martín-Rodríguez mail ,
López-Izquierdo
